The proposed technology consists of a portable device for monitoring the freshness of fish, based on its smell. The device is based on a gas sensor and pattern recognition software to correlate the sensor signal to the freshness of the food. The technology is designed for its integration into domestic or industrial refrigerators.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 1 - 15 of 16
The compact-GC platform is a MEMS-based analytical module for the purge&trap pre-concentration and (gas)-chromatographic separation of a sample. The two analytical MEMS (pre-concentrator and GC column) are interconnected by means of a MEMS microfluidic manifold. The microfluidic manifold interconnects the analytical MEMS, but it also acts as injector through the integrated micro-valves.
Digital Eye is an innovative, rapid and high-precision intelligent computer vision system for the non-destructive and contactless evaluation of quality and shelf-life of whole or fresh-cut fruit and vegetables. It integrates advanced vision and artificial intelligence technologies to estimate parameters useful to evaluate the quality of fruit and vegetables, during both the harvesting phase and the cold chain.
Method for extracting, with high yield, phycobiliproteins from cyanobacterial and/or algal biomass, obtaining aqueous extracts characterized by high concentration of pigments (4-5 mg/mL) and a purity, at least equal to food/cosmetic grade (P≥2).
We propose a portable chemical analysis system capable of identifying chemical substances at trace concentrations (sub-ppm), even in case of a complex matrix of interfering species.
The procedure enables the fabrication of nanocomposite membranes filled with suitable amounts of exfoliated bidimensional crystals. These are obtained with an advanced wet-jet milling technique, which provides desired thickness and lateral size of nanofillers through the pulverization and colloidal homogenization of bulk nanomaterials. The bidimensional crystals are dispersed in fluids and suitably delivered inside polymeric matrixes exhibiting a singular morphology.
WembraneX is an Italian start-up born with the ambition to make a significant contribution to UN Sustainable Goal 6 - Ensure Access to Clean Water and Sanitation for all by 2030.
The invention is about the development of a device and its methodology for measuring the active and reactive sound intensity from the impedance computation. The active intensity is calculated directly in the frequency domain multiplying the complex impedance and power spectrum of the air particle velocity. A second line of post-processing is applied to obtain the overall complex sound intensity.
This invention comprises an interrogation and readout differential method for chemical sensors based on Surface Plasmon Resonances (SPR). The integration of the SPR sensing unit (chip or other), as intermediate reflecting element of a Fabry-Perot (FP) optical resonator, is the starting point for the application of this method.
Quartz tuning forks are employed in scanning atomic force microscopy (AFM), as well as in some derived techniques, as high sensitivity detectors of interactions, of both conservative and dissipative kind, between the AFM nanometric probe and the investigated surface. However, the contributions of the two kinds of interaction result as convoluted in the sensor response, preventing fully quantitative measurements of the quantities of interest.
The technology concerns planar optical antennas composed of thin metal films and dielectric materials for the efficient direction of the light emitted by light sources, such as fluorescent molecules and bio-markers. They consist of a reflector layer, adjacent to the substrate, and a director, semi-reflective, between which the emitter is positioned, integrated into a homogeneous dielectric layer.
This technology describe the synthesis of cross-linked polymeric materials in the form of macroporous gels based on poly (2-hydroxyethyl methacrylate), capable of sequestering the anticoagulant heparin from aqueous solutions, physiological solutions and biological fluids. They are morphologically elastic and mechanically stable materials, and show high specificity and selectivity for heparin as demonstrated by the negligible adsorption of specific blood proteins such as antithrombin III, albumin and total proteins.
AIS aim is a robotized inclinometer measurement in standard inclinometer boreholes. The deep measurements have multiple applications, including: evaluating the rate of deep-seated ground deformation in landslide areas, evaluating the volume of deep-seated landslides and assessing landslide hazards. The AIS is composed by an electronic control manager, an inclinometer probe and an electric motor equipped with a high precision encoder for handling and continuous control of the probe in the borehole.
The development of an innovative screening platform of natural marine extracts guided by biological assays represents one of the main products developed within the Antitumor Drugs and Vaccines from the SEA (ADViSE) project which aims to provide a new vision in Drug Discovery processes.