B-ME developed the first thermoplastic composite electrode film based on bio-derived and biodegradable polyesters and carbon nano-fibers. It is metal-free, highly electrically conductive and possess good thermo-mechanical properties, a challenging combination of three features in a single product. This is the first-of-its-kind product, as, to the best of our knowledge, no thermoplastic biobased electrode film has been effectively produced and used so far.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 1 - 12 of 12
The compact-GC platform is a MEMS-based analytical module for the purge&trap pre-concentration and (gas)-chromatographic separation of a sample. The two analytical MEMS (pre-concentrator and GC column) are interconnected by means of a MEMS microfluidic manifold. The microfluidic manifold interconnects the analytical MEMS, but it also acts as injector through the integrated micro-valves.
The portable device is intended to assess exposure to electromagnetic fields produced by an MRI equipment. The device (dosimeter) allows to improve the analysis and study of the problems related to the exposure of the operators, starting from the technical-scientific aspects related to the exposure, also allowing to create a manual of best practices as well as to improve the professional training of operators.
The technology has been developed over the past 25 years, implementing new innovative components during time. The methodology provides a set of 2D acoustic images in different frequency intervals, for revealing the structural damage (detachments, delaminations, structural weakening) in multi-layer structures and artworks (mural paintings, frescoes, ceramic panels, panel paintings). Recently, interesting results have been obtained in studies of the water related deterioration effects on antique masonry structures.
VisLab laboratory of IMM possesses a latest generation Raman micro-spectroscope equipped for vibrational measurements with high spatial and spectral resolution, at controlled temperature and in fast-imaging. The apparatus can be used to collect information and chemico-physical maps without the need for sample preparation and alteration, therefore for non-destructive studies and in operating conditions.
The invention consists of a method and apparatus for the delivery at low pressure (equal to or less than 10-7 Torr) of monoatomic fluorine for reaction with surfaces in an ultra-clean environment. Thanks to the low pressure values involved in the proposed method, the risks associated with the use of fluorine are reduced to a minimum.
"Transitional Wearable Companions'' (TWC) are interactive, multisensory, animal-shaped soft toys, developed as a support tool for early intervention in neurodevelopmental disorders (NDD), with particular reference to Autism Spectrum Disorders (ASD). Thanks to internal electronics, TWC can emit coloured lights, nice sounds and mild vibrations when touched on the paws. Such stimulations are usually very reinforcing to children and attract their attention.
Electrochromism is an optoelectronic characteristic of particular interest because it can be exploited in the creation of technologies such as smart windows (Smart Windows) to promote energy efficiency, automotive, sensor or visualization devices. Electrochromic materials change their optoelectronic characteristics, showing different colors depending on the applied electric field.
The technology refers to a system for the safety and control of the mobility of vehicles, pedestrians, and mass transport users, in conventional and advanced contexts and is suitable for use as an infrastructure for the production/sharing of information and data, aimed at monitoring and intervention in critical areas by offering specific functions concerning the detection of potentially dangerous situations or the optimization of resources.
The proposed device is a semi-transparent screen that allows simultaneous viewing of what is beyond the screen and the images projected onto its surface. It consists of two thin glass plates with reflective elements arranged as microlenses, embedded in a resin. The projector's light is reflected by the elements towards the user's eye, while external light passes through the transparent layers without distortion. The transparency and brightness of the screen can be adjusted by modifying the reflective elements.
Our team can develop low-cost ultra-flexible sensors integrated on plastic substrate for volatile organic compounds (VOCs) and gas detection. These devices combine scalable fabrication technologies, implementing active materials such as nanostructured metal oxides or stack of nanostructures decorated with metal nanoparticles, thus enabling a high sensitivity (in the range of hundreds of ppb). These devices can be applied to numerous industrial and commercial sectors and they can be embedded in systems that are more sophisticated.
IMM has developed tactile sensors for the detection of objects and surface and for the handling of objects with humanoid robots (e-skin). These devices can be integrated on ultra-flexible and high conformable substrates and they can be used for multiple applications: 1) for a correct interaction with objects distributed in complex environment; 2) for a safe short-range interaction between humanoid robot and humans; 3) for fabricating smart wearables for the detection of biometric parameters (e.g. heartbeat); 4) for remotely control rovers with wearable gadgets.