The Proof-of-Concept A.L.I.C.E. or "Actuators based on Light sensitive CompositE" aims at the development of innovative materials through 3D/4D printing processes and uses them as actuators in the fields of photovoltaics, concentrated solar power, thermodynamic solar, and other applications such as optical deflectors, optical microvalves, and optical switches.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 1 - 15 of 15
The compact-GC platform is a MEMS-based analytical module for the purge&trap pre-concentration and (gas)-chromatographic separation of a sample. The two analytical MEMS (pre-concentrator and GC column) are interconnected by means of a MEMS microfluidic manifold. The microfluidic manifold interconnects the analytical MEMS, but it also acts as injector through the integrated micro-valves.
The portable device is intended to assess exposure to electromagnetic fields produced by an MRI equipment. The device (dosimeter) allows to improve the analysis and study of the problems related to the exposure of the operators, starting from the technical-scientific aspects related to the exposure, also allowing to create a manual of best practices as well as to improve the professional training of operators.
Molecular doping (MD) is a doping method based on the use of liquid solutions. The dopant precursor is in liquid form and the material to be doped is immersed in the solution. During the immersion process, the molecule containing the dopant atom is deposited on the surface of the material forming a self-assembled monolayer, that is, ordered and compact. Through a subsequent heat treatment, the molecule decomposes and the dopant diffuses.
We propose a portable chemical analysis system capable of identifying chemical substances at trace concentrations (sub-ppm), even in case of a complex matrix of interfering species.
The invention is about the development of a device and its methodology for measuring the active and reactive sound intensity from the impedance computation. The active intensity is calculated directly in the frequency domain multiplying the complex impedance and power spectrum of the air particle velocity. A second line of post-processing is applied to obtain the overall complex sound intensity.
"Transitional Wearable Companions'' (TWC) are interactive, multisensory, animal-shaped soft toys, developed as a support tool for early intervention in neurodevelopmental disorders (NDD), with particular reference to Autism Spectrum Disorders (ASD). Thanks to internal electronics, TWC can emit coloured lights, nice sounds and mild vibrations when touched on the paws. Such stimulations are usually very reinforcing to children and attract their attention.
The development of new materials with near-infrared emission (NIR, 700 – 1000 nm) represent an important target in the technological progress of innovative active components for OLED devices (including flexible ones), surveillance systems, autonomous driving, night vision sensors, fiber optic telecommunications and medical systems. In all these fields it still lacks a commercial NIR-OLED technology.
Optical backplane for interconnection between boards of a high-capacity ICT apparatus, data-center, server and the related automatic assembly method. The solution is based on optical connections between boards with an optimized layout on a support with mechanical constraints that involve controlled deformations of commercial optical fibers with standardized connectors. The entire interconnection circuit is divided into N independent circuits, each of which makes the connections between all the boards (Full-Mesh).
The metasurface optomechanical modulator is a device designed to modulate the amplitude, phase and polarization of a beam of electromagnetic radiation, independently, or simultaneously, according to prescribed paths in the parameter space (for example, as regards polarization, paths on the Poincaré sphere). The concept of our device can be applied to the entire spectrum of electromagnetic waves: from radio frequency, to microwaves (GHz), to millimeter waves (THz), to far and near infrared radiation, and to visible light.
The technology concerns planar optical antennas composed of thin metal films and dielectric materials for the efficient direction of the light emitted by light sources, such as fluorescent molecules and bio-markers. They consist of a reflector layer, adjacent to the substrate, and a director, semi-reflective, between which the emitter is positioned, integrated into a homogeneous dielectric layer.
The Q-PLL is a nonlinear circuit which can maintain a locked state when forced by two incommensurate frequencies.
The locked state is a third frequency parametrically selected among those prescribed by the theory of three-frequency resonances in dynamical systems.
In particular, the locked frequency forms a three-frequency resonance with the frequencies of the quasi- periodic input and is closely related to the pitch perception of complex sound in humans.
AIS aim is a robotized inclinometer measurement in standard inclinometer boreholes. The deep measurements have multiple applications, including: evaluating the rate of deep-seated ground deformation in landslide areas, evaluating the volume of deep-seated landslides and assessing landslide hazards. The AIS is composed by an electronic control manager, an inclinometer probe and an electric motor equipped with a high precision encoder for handling and continuous control of the probe in the borehole.
The technology refers to a system for the safety and control of the mobility of vehicles, pedestrians, and mass transport users, in conventional and advanced contexts and is suitable for use as an infrastructure for the production/sharing of information and data, aimed at monitoring and intervention in critical areas by offering specific functions concerning the detection of potentially dangerous situations or the optimization of resources.
This form describes a programmable, autonomous and stand-alone imaging system for the acquisition and processing of images containing subjects whose size is larger than 1cm (e.g. gelatinous zooplankton, fishes, litter, manufacts), form the seafloor or along the water column, in shallow or deep waters. It is capable to recognize and classify the image content through pattern recognition algorithms that combine computer vision and artificial intelligence methodologies.