Technologies

In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).

Displaying results 1 - 8 of 8

# Record card
12
Description

Current standard SPECTs, in order to achieve high resolutions, use a multi-pinholes technology that requires numerous data processing to limit the effects of image distortion. The proposed SSR-SPECT scanner, uses a parallel-hole collimator and therefore does not require numerical reprocessing of the data to obtain correct information on the images, while assuring spatial resolutions close to those of the pinholes through the acquisition of sequences of images shifted from one to another.

Thematic areas
Health & Biotech / Bio-medicals
Health & Biotech / Medical imaging & equipment
Health & Biotech / Diagnostic, Medical imaging & advanced bioimaging
# Record card
70
Description

The technology we participate to develop, called "Zinc-Finger Artificial Transcription Factors (ZF-ATFs)", allows to design, realize and select artificial genes coding for proteins capable of recognizing and binding "potentially" any DNA sequence. We used ZF-ATF technology to reprogram the expression of "beneficial" genes capable of efficiently counteracting the negative effect of mutated genes related to rare diseases.

Thematic areas
Health & Biotech / Bio-medicals
Health & Biotech / New therapies
# Record card
80
Description

Time-correlated single photon counting (TCSPC) is regarded as the “gold-standard” method for fluorescence lifetime measurements. However, TCSPC requires using highly sensitive detectors, not suitable for measurements under bright light conditions, thereby making the use impractical in clinical settings. The invention described here solves this problem by synchronizing the fluorescence detection with an external light source.

Thematic areas
Health & Biotech / Smart Devices for Health and Wellness
Health & Biotech / Diagnostic, Medical imaging & advanced bioimaging
Health & Biotech / Medical Device
Health & Biotech / Biosensors
Health & Biotech / Bio-medicals
Health & Biotech / Medical imaging & equipment
Health & Biotech / Diagnostic kits
Health & Biotech / Bio-informatics
# Record card
28
Description

The portable device is intended to assess exposure to electromagnetic fields produced by an MRI equipment. The device (dosimeter) allows to improve the analysis and study of the problems related to the exposure of the operators, starting from the technical-scientific aspects related to the exposure, also allowing to create a manual of best practices as well as to improve the professional training of operators.

Thematic areas
Health & Biotech / Bio-medicals
ICT & Electronics / Electronics and microelectronics
# Record card
101
Description

The herein described technology aims at the development of a platform of injectable hydrogels for application as drug carriers for localized delivery or in the regenerative medicine field. The use of ad-hoc synthesized poly(ether urethane)s (PEUs) as hydrogel forming materials is a common property which characterizes all the systems belonging to this platform.

Thematic areas
Health & Biotech / Micro and nanotechnology related to biological sciences
Health & Biotech / Bio-medicals
Health & Biotech / New therapies
Health & Biotech / Nanomedicine
Health & Biotech / Medical Device
Health & Biotech / Regenerative Medicine
Materials / Processes of production & treatment of materials
Materials / Plastics, polymers
# Record card
182
Description

An innovative approach for the treatment of diabetic and venous ulcers, characterized by a difficult healing process and therefore at potential risk of infection and therefore of hospitalization and amputation of the limb, is represented by the local administration of "bioactive" factors through the use of synthetic and/or biological matrices that allow a gradual and controlled release in order to obtain a better and faster healing.

Thematic areas
Health & Biotech
Health & Biotech / Bio-medicals
Health & Biotech / New therapies
Health & Biotech / Medical Device
Health & Biotech / Regenerative Medicine
# Record card
135
Description

Portable robotic device for bilateral neuromotor rehabilitation. An appropriate mechanical structure and a series of interchangeable accessories suitably designed allow the execution of various motor gestures of the upper limbs, involving different articulations and muscles. The possibility of being used with both limbs contributes to the recovery of motor coordination and facilitates the mechanism of brain plasticity. Some rotary axes the device is equipped with are motorized and sensorized.

Thematic areas
Health & Biotech
Health & Biotech / Bio-medicals
Health & Biotech / Smart Devices for Health and Wellness
Health & Biotech / Medical Device
ICT & Electronics
ICT & Electronics / Robotics and control systems
ICT & Electronics / Artificial Intelligence
# Record card
138
Description

We present a technology for the multiscale isolation (analytical-laboratory-production) of Extracellular Vesicles (VE), which overcomes the limitations of the currently available methods. As opposed to traditional "affinity-based" systems that exploit antibodies, our technology represents a radical paradigm shift in the development of affinity probes for vesicles, i.e.

Thematic areas
Health & Biotech
Health & Biotech / Smart Devices for Health and Wellness
Health & Biotech / Nanomedicine
Health & Biotech / Diagnostic, Medical imaging & advanced bioimaging
Health & Biotech / Regenerative Medicine
Health & Biotech / Care, Hygiene, Cosmetics
Health & Biotech / Biosensors
Health & Biotech / Micro and nanotechnology related to biological sciences
Health & Biotech / Bio-medicals
Health & Biotech / Diagnostic kits
Chemicals & Physics
Chemicals & Physics / Separation technologies