4Ts Game was born in ITD in 2017 to indicate a board game for teacher training, which aims to develop skills in designing collaborative learning activities. The game was originally conceived as a 'tangible' game, consisting of a board and 4 decks of paper cards which contain inputs that guide the teachers/players' design process. Subsequently the game evolved and was developed in its digital version. In this version, developed in Unity and with an underlying knowledge base in Prolog, the game is able to provide feedback to teachers regarding the design/game choices made.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 1 - 15 of 27
The technology for organic thin film transistors (OTFTs) is suitable for large area electronics, disposable electronics and "Internet of Things" applications. Circuits employing OTFTs can be realized by using very cheap printing technologies. The electrical behavior of these devices is essentially different from the behavior of silicon MOSFETs and, in order to enable circuit design, compact models specific for OTFTs are needed.
The presented technology is an electrical compact model for OTFTs that:
The Proof-of-Concept A.L.I.C.E. or "Actuators based on Light sensitive CompositE" aims at the development of innovative materials through 3D/4D printing processes and uses them as actuators in the fields of photovoltaics, concentrated solar power, thermodynamic solar, and other applications such as optical deflectors, optical microvalves, and optical switches.
AIDD is an integrated tool and a radically new way to discovery new drugs for neurodegenerative diseases (Alzheimer’s, Epilepsy, Ageing, etc.).
Time-correlated single photon counting (TCSPC) is regarded as the “gold-standard” method for fluorescence lifetime measurements. However, TCSPC requires using highly sensitive detectors, not suitable for measurements under bright light conditions, thereby making the use impractical in clinical settings. The invention described here solves this problem by synchronizing the fluorescence detection with an external light source.
The present invention relates to the biomedical sector of the treatment of lung diseases and related symptoms. In particular, the present invention provides compositions and methods based on the use of selected polymeric biomaterials, in combination with stem cells and/or their secretome, capable of synergistically improving the development, regeneration and repair of chronic lung injuries and related symptoms.
The insertion of executable programs within QR codes is a new enabling technology for many application contexts in everyday life. Every time Internet access is unavailable, QR code usage is limited to reading the data it contains without any possibility of interaction.
The technology based on cell or tissue cultures is very useful for the production of bioactive compounds. These molecules, depending on the class they belong to, can be used in the food, pharmaceutical and cosmetic industry. In particular, the developed technology is addressed to the optimization of bioactive compounds in plant cell/tissue cultures having the biosynthetic pathway of the compound of interest.
Mirrors for space applications, besides featuring suitable optical properties, should be light, resistant to mechanical stresses, and unsensitive to light-shadow thermal cycling. The standard optical materials easily fulfill optical and thermal requirements, but are fragile, and the mirrors must be thick (typically 1/6 of the diameter). For this reason they are heavy, and the only available solution is to lighten them, by removing material from the back side, still preserving the necessary mechanical robustness and optical quality.
This invention comprises an interrogation and readout differential method for chemical sensors based on Surface Plasmon Resonances (SPR). The integration of the SPR sensing unit (chip or other), as intermediate reflecting element of a Fabry-Perot (FP) optical resonator, is the starting point for the application of this method.
The object of the technology is the development of a transferable methodology from the laboratory scale to the pilot scale to be validated in the industrial setting for the treatment of basic waste of natural polymers of agro-food or manufacturing industry.
"Transitional Wearable Companions'' (TWC) are interactive, multisensory, animal-shaped soft toys, developed as a support tool for early intervention in neurodevelopmental disorders (NDD), with particular reference to Autism Spectrum Disorders (ASD). Thanks to internal electronics, TWC can emit coloured lights, nice sounds and mild vibrations when touched on the paws. Such stimulations are usually very reinforcing to children and attract their attention.
Design and testing of neoproteins with optimized nutritional value, according to needs, avoiding their degradation - thus maintaining a high production yield - and aggregation (which could make them indigestible). Neoproteins are produced and characterized in plant systems as bioreactors. We have already created zeolin, formed by the fusion of a bean seed protein with a portion of a maize seed protein.
The proposed technology is based on the concept of Power-Over-Fibre (PoF), which involves the transmission of data and power over an optical fiber. This technology is suitable for applications where traditional copper cabling is impractical or undesirable. This is the case with pantographs, where there is a large potential difference between the catenary and the earth, and therefore any electrical contact must be avoided for safety reasons. Furthermore, pantographs operate in an environment with very high electromagnetic interference (EMI).
The technology concerns planar optical antennas composed of thin metal films and dielectric materials for the efficient direction of the light emitted by light sources, such as fluorescent molecules and bio-markers. They consist of a reflector layer, adjacent to the substrate, and a director, semi-reflective, between which the emitter is positioned, integrated into a homogeneous dielectric layer.