Solid State Nuclear Magnetic Resonance spectroscopy (SSNMR) is today one of the most powerful techniques for characterizing solid and soft materials and systems. This spectroscopy allows the detailed characterization of structural and dynamic properties over large spatial (0.1-100 nm) and time (102-10-11 s) scales. Accessing these properties allows a deep knowledge of a material to be obtained and its design and optimization to be oriented.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 31 - 45 of 45
The environment as well as the food production provide a number of both natural and synthetic compounds whose effects on human being as an organism have not yet been determined nor investigated.
Recently, it has been demonstrated that Raman spectroscopy can play a fundamental role in assisting the work of the anatomopathologist by allowing classification of oncological samples with practically 100% accuracy in oncological diagnosis.
To the enterprises working in the field of nutrition/nutraceutics and drug development/repositioning, we offer the know-how and state-of-the-art instrumentation of our labs to monitor multiple relevant biological parameters at the cellular level: metabolic activity, vitality, health, but also stress and toxicity. The use of advanced imaging techniques based on fluorescent/bioluminescent probes together with the availability of time-lapse acquisitions, guarantee the cutting-edge analysis of different biological parameters over time.
The proposed system is based on a high-resolution electrocardiograph in which the electrodes are positioned on maternal abdomen. The acquired signals are processed using a completely unsupervised software for fetal ECG extraction based on independent component analysis, maternal ECG canceling and a quality index optimization. The electrocardiograph is constituted by a light-weight and light-dimension portable unit, which acquires the signals and transmit them to a computer where the analysis software runs.
The present technology deals with jewels based on shape memory alloys and fabricated through additive manufacturing. In ICMATE-Lecco laboratories, several NiTi-based rings have been fabricated through a powder bed fusion technology (selective laser melting technique).
The invention consists in a special regulation method of the horizontal axes of operating and rubbing wheels of a centerless grinding machine coupled with an opportune blade profile, allowing a continuous regulation of blade rest angle (angle between tangent to blade profile at the contact point with the work piece and the horizon, denoted by γ) and workpiece height (denoted by hw), without requiring blade substitution and/or manual regulations.
The proposing team that works at CNR ISTEC has recently patented a technology for the production of the Smart Polycrystals (SP), i.e. transparent YAG-based ceramic polycrystals (Y3Al5O12) variably doped with rare earths ions and transition metals ions. The SPs solve the problem of the reduction of the efficiency in the solid state laser systems caused by the inhomogeneous heating of the single crystals during the emission process.
This technology is based on an algorithm able to provide the probability of being asthmatic with high accuracy. This probability is based on the evaluation of respiratory function and, specifically, of forced expiratory vital capacity in the first second (FEV1), in resting conditions, and 20 minutes after administration of a bronchodilator drug.
Polymer development is approaching to a new stage of advancement in which new functionalities especially in combination with conductive polymers and nanomaterials are more effective. In this context the study of new composites is the key to enable the development of disruptive technologies as additive manufacturing. Increasing electrical conductivity open the way to a new class of objects to be prototyped rapidly at low cost with a high level of customization.
Electrochromism is an optoelectronic characteristic of particular interest because it can be exploited in the creation of technologies such as smart windows (Smart Windows) to promote energy efficiency, automotive, sensor or visualization devices. Electrochromic materials change their optoelectronic characteristics, showing different colors depending on the applied electric field.
IMM has developed tactile sensors for the detection of objects and surface and for the handling of objects with humanoid robots (e-skin). These devices can be integrated on ultra-flexible and high conformable substrates and they can be used for multiple applications: 1) for a correct interaction with objects distributed in complex environment; 2) for a safe short-range interaction between humanoid robot and humans; 3) for fabricating smart wearables for the detection of biometric parameters (e.g. heartbeat); 4) for remotely control rovers with wearable gadgets.
We present a technology for the multiscale isolation (analytical-laboratory-production) of Extracellular Vesicles (VE), which overcomes the limitations of the currently available methods. As opposed to traditional "affinity-based" systems that exploit antibodies, our technology represents a radical paradigm shift in the development of affinity probes for vesicles, i.e.
The working principle of VTTJ is extremely simple. Two parts (at least one with tube shape) are screwed one into the other with a mechanical interference that creates a metallic seal. One part presents a cylindrical slot, the other presents a conical ring, whose diameter is slightly larger than the one of the cylindrical slot. When the two parts are screwed together, a plastic deformation occurs in the mechanical interference region.
X-ray imaging techniques can work in i) "full-field mode" in which the object to study (or part of it) is completely illuminated by the X-ray beam; ii) "scanning mode" in which an X-ray beam, focused through an opportune optics, illuminates in succession contiguous areas of the sample under examination, and the transmitted wave is measured by a detector placed at a proper distance from it. One of these X-ray scanning microscopes is available at the facility (X-ray MicroImaging, XMIL@b) of the Institute of Crystallography (CNR-Bari).