4Ts Game was born in ITD in 2017 to indicate a board game for teacher training, which aims to develop skills in designing collaborative learning activities. The game was originally conceived as a 'tangible' game, consisting of a board and 4 decks of paper cards which contain inputs that guide the teachers/players' design process. Subsequently the game evolved and was developed in its digital version. In this version, developed in Unity and with an underlying knowledge base in Prolog, the game is able to provide feedback to teachers regarding the design/game choices made.
Technologies
In this section it is possible to view, also through targeted research, the technologies inserted in the PROMO-TT Database. For further information on the technologies and to contact the CNR Research Teams who developed them, it is necessary to contact the Project Manager (see the references at the bottom of each record card).
Displaying results 1 - 14 of 14
A biosensor based on magnetic microspheres functionalized with a DNA-aptamer was developed for the specific biomonitoring of biological contaminants (mycotoxins) in urine.
Current standard SPECTs, in order to achieve high resolutions, use a multi-pinholes technology that requires numerous data processing to limit the effects of image distortion. The proposed SSR-SPECT scanner, uses a parallel-hole collimator and therefore does not require numerical reprocessing of the data to obtain correct information on the images, while assuring spatial resolutions close to those of the pinholes through the acquisition of sequences of images shifted from one to another.
Time-correlated single photon counting (TCSPC) is regarded as the “gold-standard” method for fluorescence lifetime measurements. However, TCSPC requires using highly sensitive detectors, not suitable for measurements under bright light conditions, thereby making the use impractical in clinical settings. The invention described here solves this problem by synchronizing the fluorescence detection with an external light source.
The present invention relates to the biomedical sector of the treatment of lung diseases and related symptoms. In particular, the present invention provides compositions and methods based on the use of selected polymeric biomaterials, in combination with stem cells and/or their secretome, capable of synergistically improving the development, regeneration and repair of chronic lung injuries and related symptoms.
Molecular doping (MD) is a doping method based on the use of liquid solutions. The dopant precursor is in liquid form and the material to be doped is immersed in the solution. During the immersion process, the molecule containing the dopant atom is deposited on the surface of the material forming a self-assembled monolayer, that is, ordered and compact. Through a subsequent heat treatment, the molecule decomposes and the dopant diffuses.
The herein described technology aims at the development of a platform of injectable hydrogels for application as drug carriers for localized delivery or in the regenerative medicine field. The use of ad-hoc synthesized poly(ether urethane)s (PEUs) as hydrogel forming materials is a common property which characterizes all the systems belonging to this platform.
We propose a compact innovative spectroscopy system operating in the UV range. In the actual version, designed for gas, it exhibits: an aluminium tubular optical chamber (length can be adjusted; currently is 20 cm); a cheap commercial UV LED; a SiC visible blind UV detector designed and manufactured at the CNR-IMM facilities. The team developed also the electronic chain for wireless remote real time read out; while able to deal with pA current levels, it uses very cheap components and construction technology.
The procedure enables the fabrication of nanocomposite membranes filled with suitable amounts of exfoliated bidimensional crystals. These are obtained with an advanced wet-jet milling technique, which provides desired thickness and lateral size of nanofillers through the pulverization and colloidal homogenization of bulk nanomaterials. The bidimensional crystals are dispersed in fluids and suitably delivered inside polymeric matrixes exhibiting a singular morphology.
The development of new materials with near-infrared emission (NIR, 700 – 1000 nm) represent an important target in the technological progress of innovative active components for OLED devices (including flexible ones), surveillance systems, autonomous driving, night vision sensors, fiber optic telecommunications and medical systems. In all these fields it still lacks a commercial NIR-OLED technology.
The proposed technology is based on the concept of Power-Over-Fibre (PoF), which involves the transmission of data and power over an optical fiber. This technology is suitable for applications where traditional copper cabling is impractical or undesirable. This is the case with pantographs, where there is a large potential difference between the catenary and the earth, and therefore any electrical contact must be avoided for safety reasons. Furthermore, pantographs operate in an environment with very high electromagnetic interference (EMI).
The platform allows the deployment of a sensor network with peripheral nodes spread on the crop fields or on the environment for the monitoring of crop parameters/environmental parameters. The network architecture integrated LoRa peripheral nodes for short-medium range communication and star-center NB-IoT based for long range communication. It includes a web server and MySQL database for data storage and visualization. The network architecture is scalable to adapt to the area to monitor.
The Q-PLL is a nonlinear circuit which can maintain a locked state when forced by two incommensurate frequencies.
The locked state is a third frequency parametrically selected among those prescribed by the theory of three-frequency resonances in dynamical systems.
In particular, the locked frequency forms a three-frequency resonance with the frequencies of the quasi- periodic input and is closely related to the pitch perception of complex sound in humans.
The proposed system is based on a high-resolution electrocardiograph in which the electrodes are positioned on maternal abdomen. The acquired signals are processed using a completely unsupervised software for fetal ECG extraction based on independent component analysis, maternal ECG canceling and a quality index optimization. The electrocardiograph is constituted by a light-weight and light-dimension portable unit, which acquires the signals and transmit them to a computer where the analysis software runs.